Universal 1005 Spécifications

Naviguer en ligne ou télécharger Spécifications pour Commutateurs de réseau Universal 1005. Universal 1005 Specifications [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 53
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
VALICHANGER
OPERATIONS MANUAL
SERIES AC1005/AC2221
ARL Listed STD: UL 756
American Changer Corp Parts & Service:(888)741-9840
1400 NW 65
TH
Place Sales:(800)741-9840
Ft. Lauderdale, FL 33309 Fax:(954)917-5204
Internet Address
: www.americanchanger.com
Service Questions?: e-mail: [email protected]
Table of Contents
SEC. A: SET-UP & INSTALLATION
Uncrating and Setup
3
Mounting instructions
3
Programming the Changer
4-14
Functional Description
14-15
Out-of-Service Conditions
15-16
Equipment Indicator Lights
16
Hopper Coin/Token Sizes
17
MLB Connector Pinouts
17
Coinco BA30 Series Error Codes
17
Validator Interfaces
18
SECTION B: EQUIPMENT INFO.
Coinco MAG Validator Section
19-25
MEI Mars AE2600 Series
Validator Section
26-30
Money Controls MKIV Universal
Hopper Section
31-37
Un-jamming the Hopper
34-36
SECTION C: TROUBLESHOOTING
INFORMATION
Technical Flow Diagram
38
Troubleshooting Guide
39-40
SECTION D: PARTS LISTS
AC1005/AC2221 Parts List
41
MKIV Hopper Parts List
42
Coinco Parts List
43-46
Mars AE2600 Series Parts List
47-49
SECTION E: SERVICE CENTERS
Coinco
50
Mars (MEI)
51-53
Rev. UNV_F06 Apr.’05
Specifications
Operating voltage 120 VAC +10/-15 %
Power consumption Controller: 10W, Hopper: 48W Max
Validator: MAG=60W Max
AE2602=50W Max
Operating temperature 32 - 130 degrees Fahrenheit
Interface to Hoppers 24Vdc, ccTalk Serial Protocol
Interface to Validators 24Vdc, MDB or Pulse Protocol
Warranty
CoinCo MAG & MEI (Mars) AE2600 Series Validators are
under warranty for two years from date of purchase.
COVERED
¥ Defects in workmanship or materials
NOT COVERED
¥ Damage caused by physical abuse
¥ Misapplication
¥ Vandalism
¥ End user’s attempt to repair item on his own
¥ Cleaning & maintenance
It is the End User’s responsibility to follow cleaning &
maintenance procedures outlined on pages 22-23, and 29.
Any unit coming in for repair requiring only a cleaning will
be charged a flat rate of $65.00 plus shipping and handling.
Dispensing System and Logic Board
The coin dispenser and logic board are under warranty for one
year from date of purchase.
COVERED
¥ Defects in workmanship or materials
NOT COVERED
¥ Damage caused by physical abuse
¥ Misapplication
¥ Vandalism
¥ End user’s attempt to repair item on his own
A Return Material Authorization number (RMA #) must be
obtained before returning a unit for repair. A copy of invoices
must accompany any and all warranty work
Vue de la page 0
1 2 3 4 5 6 ... 52 53

Résumé du contenu

Page 1 - VALICHANGER

1 VALICHANGER OPERATIONS MANUAL SERIES AC1005/AC2221

Page 2 - Attention Please

10 STANDBY OPERATION Power-ON the changer, and allow it to run through its start-up procedure, which may take up to a minute or more, before attem

Page 3 - UNCRATING AND SETUP

11on your particular validator (Factory settings from American Changer enable all bills on the validator’s DIP switches, so they should not be chan

Page 4 - CHANGER

12PAYOUT OPTIONS PAYOUT: There are a total of eight different ways that this menu can appear, as seen in the Program Flow Chart on pgs. 6-7 in the

Page 5

13the token payout per one-dollar bill (‘$1 L’) and change given (‘$1 R’). This is followed by the token and change payout per $2 bill (if enabled)

Page 6

14pulse validators that are inside the unit. If ‘1’ is chosen, then the program will further prompt for whether the validator is enabled using a lo

Page 7

15thickness). Since all coins we vend are from 20-30mm, this rarely changes. 4. When a bill is finally inserted into the validator bill slot, the

Page 8

16obstruction. If nothing is found, unit may need servicing or replacement. 4. CoinAcc. CreditS – The coin acceptor’s Credit Sensor is either bloc

Page 9

1712 pin female connector MotorCoin counting optic Hopper coin bin (Dump the coins into this hole; 1600 coins max.) HOPPER COIN/TOKEN SIZES The

Page 10

18VALIDATOR INTERFACES 18-PIN Interface Connector PLUG KEY Interfacing the CoinCo BA30SA with the ValiChanger Connect wires 4 & 1

Page 11

19 COINCO MAG VALIDATOR SECTION PAGE Removing the Bill Box 20 Removing a bill jam 20 Setting the bill t

Page 12

2 Attention Please: To ensure the most trouble-free machine operation, we recommend plugging all our machines into a DEDICATED AC outlet. (Thi

Page 13

20Removing the bill box. To remove the 500 bill stacker from the CoinCo validator, follow the picture below. REMOVING A BILL JAM From time to ti

Page 14

21SETTING THE BILL ACCEPT DIP SWITCHES

Page 15

22 CLEANING THE BILL VALIDATOR Refer to the pictures and the procedure on the next page to clean the bill validator eve

Page 16

23 MAG CLEANING: IF ANY OF THESE PROCEDURES ARE PERFORMED TO YOUR VALIDATOR AFTER IT IS RETURNED UNDER A WARRANTY REPLACEMENT, YOU WILL BE SUBJECTE

Page 17

24REPLACING THE BELTS Every 2-3 years the belts on the CoinCo will wear out. To replace them, remove the validator components down to the picture

Page 18

25 MAG TROUBLESHOOTING GUIDE This Troubleshooting Guide is intended to help locate problems within the bill acceptor. If a bill acceptor cannot be

Page 19

26 MEI MARS AE2600 SERIES BILL VALIDATOR OPERATIONS MANUAL MEI MARS AE2600 SERIES VALIDATOR SECTION

Page 20 - REMOVING A BILL JAM

27 REMOVING THE BILL BOX CLEARING A BILL JAM Remove the Magazine and the LED Housing to gain access to the Bill Path, wh

Page 21

28SETTING THE BILL TYPES ACCEPTED XXFACTORY DEFAULT IS ALL SWITCHES SET TO “OFF”! (SETTINGS MARKED BY X’s)

Page 22 - CLEANING THE BILL VALIDATOR

29 Cleaning You can clean the bill acceptor while it is still mounted in the machine (refer to Figure 3 below). 1. Remove power from the machine. 2

Page 23

3UNCRATING AND SETUP Remove your AC1005/AC2221 series changer from the shipping box. Open the door. (The T-handle(s) are the screw-in type and t

Page 24 - REPLACING THE BELTS

30 Status LED A Status LED provides assistance in diagnosing the condition of the Series AE2600. The following is a description of the LED codes,

Page 25 - MAG DIAGNOSTIC CODES

31 MKIV UNIVERSAL HOPPER SERVICE MANUAL INDEX 1. Coin box removal & assembly 32-33 2. Exit window r

Page 26

321. COIN BOX REMOVAL 1. Place the hopper in front of you as shown, (looking at the outside of the ‘coin box’). Refer to FIG 1. 2. Remov

Page 27 - CLEARING A BILL JAM

33COIN BOX ASSEMBLY (cont.) 2. Line up the ‘center plate’ & ‘coin box’ as shown below. FIG 12a. 3. Route the ribbon cable as shown below.

Page 28

343. LOGIC BOARD REPLACEMENT 1. First, remove the ‘coin box’, section 1. This will then enable access to the ‘logic board’. 10-way ribbon

Page 29 - Cleaning

355a. TRACK PLATE ASSEMBLY The following 3 sketches show how to take the ‘track plate’ apart. The following 3 sketches show how to assemble th

Page 30 - Status LED

365b. TRACK PLATE REPLACEMENT 1. The gray shaded area, in FIG 7b, is the ‘track plate’ guide path. FIG 7b. 2. Once the ‘track plate’ is i

Page 31 - 4. End plate removal 34

376. GEAR BOX ASSEMBLY 1. Remove the end plate. Section 4. 2. Remove the ‘elevator track’ & ‘final drive gear’. Section 5. 3. Remo

Page 32 - 1. COIN BOX REMOVAL

38 TECHNICAL FLOW DIAGRAM Before starting this procedure, ensure the changer is plugged in, the ON/OFF switch is ON, the hopper is full of coins,

Page 33 - 2. EXIT WINDOW REPLACEMENT

39 PROBLEM: A. The changer is completely dead. (The green LED on the Power Supply Board is not lit.) B. The “Out-of-Service” LED is li

Page 34 - 5. TRACK PLATE REMOVAL

4PROGRAMMING THE AC1005/AC2221 SERIES CHANGER Section Page(s) Program Flow Chart 5-9 Standby Operation 10

Page 35 - 5a. TRACK PLATE ASSEMBLY

40 PROBLEM: G. The Main Logic Board Display is showing a “HopperX NoComm” Error Message. H. The changer is giving the wrong payouts. I.

Page 36 - 5b. TRACK PLATE REPLACEMENT

41 PARTS LIST FOR THE AC1005/AC2221 AC1005/AC2221 PARTS LIST (SHOWN ABOVE) 1. AC1011 - CABINET COMPLETE W/

Page 37 - 7. MOTOR REPLACEMENT

42 #1#2 #3#4 #5A#6#7#8#10#11#16 #17#18 #12#13 #14 #15#18 #19#20#22 #23 #21#5B#1 - 1041-24-01 Motor #2 - 1041-24-02 Motor Side Cover #3 - 1041-

Page 38 - TECHNICAL FLOW DIAGRAM

43 COINCO PARTS LIST PICTURE # #1 #2 #3 #4 #5 #6 #7 PART # MP90-1-1 MP91-1-2 MP90-1-3 MP90-1-4 MP91-1-5 MP90-1-6

Page 39 - TROUBLESHOOTING GUIDE

44 COINCO PARTS BREAKDOWN PICTURE # #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #10 #11 #12 #13 #14 #15 #16 PART # MP90-2-1 MP90-

Page 40

45 COINCO PARTS BREAKDOWN PICTURE # #1 #2 #3 #4 #5 #8 #9 #10 #11 #13 #14 #15 #16 #17 #18 #19 #21

Page 41

46 MP90-4-IF 3 4COINCO PARTS BREAKDOWN PICTURE # #1 #2 #3 #4 #5 PART # MP90-

Page 42

47 #8 MARS AE2600 SERIES 24VDC PARTS BREAKDOWN PICTURE # #1 #2 #3 #4 #5 #6 #7 #8 #9 PART

Page 43 - COINCO PARTS LIST

48 PICTURE # #1 #2 #3 #4 #5 #6 #7 #8 PART # AE93-2-1 AE93-2-2 AE93-2-3

Page 44 - MP91-2-10

49 PICTURE # #1 #2 #3 #4 PART # AE93-1-5 AE93-3-2 AE93-3-3 AE93-3-3 CONTINUED

Page 45

5AC1005/AC2221 SERIES CHANGER PROGRAM FLOW CHART Pages 6-7 Page 8-9 SW Version

Page 46 - MP90-4-IF

50 Arizona 3226 S. Fair Lane Tempe, AZ 85282 Phone: 602-431-0632 Chris Mattingly California 11618 E. Washington Blvd. Suite # J Whittier, C

Page 47

51 ALABAMA Birmingham Vending Co. Mr. Gerald Spiegelman 540 N. 2nd Avenue Birmingham, AL 35204 Phone: 205-324-7526 Fax: 205-322-6639 Email:

Page 48 - CONTINUED

52 LOUISIANA Sur Serv Corp. Mr. Julian Ortiz 2920 Kingman Street Suite 118 Meltaire, LA 70006 Phone: 504-887-1661 Fax: 504-887-9081 Email: surser

Page 49

53 OKLAHOMA Aeco Sales & Service Ms. Kacy Parker 619 North Broadway Tecumseh, OK 74873 Phone: 800-682-0358 or 405-598-2915 Fax: 405-598-5506

Page 50

6AC1005/AC2221 SERIES CHANGER PROGRAM FLOW CHART (Continued on pg. 7)

Page 51

7AC1005/AC2221 SERIES CHANGER PROGRAM FLOW CHART (Continued from pg. 6) SW Version UNV_F06 PA

Page 52

8AC1005/AC2221 SERIES CHANGER PROGRAM FLOW CHART (Continued on pg. 9) SW Version UNV_F06

Page 53

9 AC1005/AC2221 SERIES CHANGER PROGRAM FLOW CHART (Continued from pg.8) SW Version

Commentaires sur ces manuels

Pas de commentaire